Peformance
- A variety of filters and work surfaces available to suit your specific experimental needs. (refer to accessory section)
- High-quality polyester fiber pre-filter for trapping larger particles and increasing the life of the main HEPA filter.
- Large-capacity blower maintaining sufficient intake flow rate and reducing noise. (less than 55 dB under normal operation)
- Fluorescent light installed outside the workspace in order to prevent the airflow hindrance as well as the contamination while maintaining illumination intensity.
Convenience
- Easy monitoring of the internal airflow speed thanks to built-in anemometer.
- Comfortable front access to cartridge type of filters for easy replacement.
- Built-in utility hole for easily routing the cords or wires of the equipment placed inside the hood.
- Fully or half openable front door for convenient transport of experimental apparatuses and equipment into or out of the workspace.
Safety
- Efficiency and capacity of activated carbon filters: BS 7989:2001
- Structure, electrical outlet, lighting, and sound level: BS 7258-1:1994
- Local smoke, large volume visualization, face velocity, and tracer gas: ANSI/ASHRAE 110-1995 and NF EN 14175-1
Digital controller
Anemometer
Performance
- A variety of filters and work surfaces available to suit your specific experimental needs. (refer to accessory section)
- High-quality polyester fiber pre-filter for trapping larger particles and increasing the life of the main HEPA filter.
- Large-capacity blower maintaining sufficient intake flow rate and reducing noise. (less than 55 dB under normal operation)
- Fluorescent light installed outside the workspace in order to prevent the airflow hindrance as well as the contamination while maintaining illumination intensity.
Convenience
- Easy monitoring of the internal airflow speed thanks to built-in anemometer.
- Comfortable front access to cartridge type of filters for easy replacement.
- Built-in utility hole for easily routing the cords or wires of the equipment placed inside the hood.
- Fully or half openable front door for convenient transport of experimental apparatuses and equipment into or out of the workspace.
Safety
- Efficiency and capacity of activated carbon filters: BS 7989:2001
- Structure, electrical outlet, lighting, and sound level: BS 7258-1:1994
- Local smoke, large volume visualization, face velocity, and tracer gas: ANSI/ASHRAE 110-1995 and NF EN 14175-1
Model | DLH-01G | DLH-11G | |||
---|---|---|---|---|---|
Controller | Microprocessor control | ||||
Face velocity | Initial set point: 0.4m/s, 80fpm | ||||
Air flow meter | Swing vane type | ||||
Main filter | Chemical Filter (optional 6 different filters) | ||||
Pre filter | Washable high efficiency nylon filter | ||||
Materials | Main body, window (front / side) | 2.0mm steel (epoxy powder-coated), 8mm / 6mm thick acrylic resin | |||
Work surface | Optional 6 different work surfaces | ||||
Fluorescent light intensity | > 600lux | ||||
Noise level | 55dB under normal operation | ||||
Dimension(W×D×H) | Interior (mm / inch) | 880×640×800 / 34.6×25.2×31.5 | 1180×640×800 / 46.5×25.2×31.5 | ||
Exterior without stand (mm / inch) | 900×660×1250 / 35.4×26×49.2 | 1200×660×1250 / 47.2×26×49.2 | |||
Exterior with stand (mm / inch) | 900×660×1985 / 35.4×26×78.1 | 1200×660×1985 / 47.2×26×78.1 | |||
Net weight (body) (kg / lbs) | 100 / 220.5 | 118 / 260.1 | |||
Net weight (body + stand) (kg / lbs) | 120 / 264.6 | 140 / 308.6 | |||
Electrical requirements (230V) | 50Hz, 0.6A | 60Hz, 0.7A | 50Hz, 0.6A | 60Hz, 0.7A | |
Cat. No. | AAHB2002K | AAHB2002K | AAHB2012K | AAHB2012K | |
Electrical requirements (100V, 120V) | 100V, 50Hz, 1.5A | 120V, 60Hz, 1.3A | 100V, 50Hz, 1.5A | 120V, 60Hz, 1.3A | |
Cat. No. | AAHB2004U | AAHB2003U | AAHB2014U | AAHB2013U |
※ Above specifications can be changed without prior notice.